The importance of green and sustainable materials in civil engineering is undeniable. Alongside modern practices that improve the properties of standard building materials, there are ways to revive forgotten techniques, including straw bale buildings. Straw bales are load-bearing structures, which are applied based on handed-down experience and lack standard approaches in testing, design, and application. Therefore, a goal ahead is to describe every aspect of the process in technical detail. The objective of this paper is to highlight practical ideas for testing straw bales on a hydraulic press machine and to provide a basic statistical investigation of the results obtained. Two basic series were prepared, one without a side barrier and the other with a side barrier. The reason for this was to delineate the limits of the real behaviour of the straw bale on the load bearing wall of the house. Due to the assumed slight embedment of adjacent bales, the real result were within these limits. The experimental plan, basic results, simplified correlations, and statistical evaluation are presented. Recommendations for a further testing and evaluation are provided. As expected, the results with and without the lateral barrier differ by almost 18% for the true strain.